A boiler not firing up on a chilly monday morning can be a nightmare and a headache, meaning something is not quite right with the boiler. But before you call a professional, some things and simple checks might save your day. However, if there is an issue with the pilot light or boiler burner, it is better to leave things to an expert. As we all know, serious boiler problems can lead to fatal situations. Therefore, it is best to avoid dealing with such issues and call a gas safe registered engineer to fix them. Therefore, if you are someone who:
Here are common boiler reasons why your boiler does not ignite, the meaning of error codes displaying on your boiler and how to fix these issues.
Every boiler needs a small amount of electricity to fire up. Considering that, here are some causes why your boiler has no power:
Boiler Brand | Standard Boiler Fuse Lockout Codes |
Worcester | FD 231, C1 264, Thermal Fuse Lockout |
Baxi | E317, OFF OFF OFF, E13 |
Glow-worm | Green LED off, F17, F76, F83 |
Ideal | – |
Vokera | – |
Get A Quotation
Feel Free To Contact Us For Free Consultation.
Undoubtedly, insufficient gas supply can prevent boiler ignition. There are a few reasons your home’s gas supply pressure might be low.
Low gas pressure is a result of your gas metre being frozen. Your common gas supply issues can also be because of the gas valve, which would naturally open to provide more gasoline.
Moreover, if it is broken or malfunctioning, the gas cannot enter the chamber, preventing the boiler from firing up.
Boiler Brand | Common Boiler Faults Concerning the Gas Supply |
Worcester | EA |
Baxi | E133 |
Ideal | Is the Gas Pressure available at the Boiler (> 18mBar) |
Glow-worm | – |
Vokera | – |
Your boiler may reset to its factory default settings if there has recently been a power outage or a time shift, which would make it fire at the incorrect time.
Another reason could be an outdated or old thermostat that misreads the temperature and interferes with ignition.
If your thermostat is too low or placed too close to a heat source, then your boiler won’t ignite
Boiler Brand | Standard Boiler Thermostat/Timer Error Codes |
Worcester | E9 224 |
Baxi | E110, E20, E.04 – .08, E20, E28, E40, E50,E110, E130, E163 |
Ideal | – |
Vokera | A02, A77, E020, E077 |
Glow-worm | – |
You probably have air trapped in your radiators if you’ve noticed that the upper and bottom portion of the boiler is not heating.
Central heating circulates hot water with the help of pipes and radiators. With time, small air pockets are formed within the boiler, and as air is lighter than water, they emerge on top of the boiler, leading to the boiler not firing and running inefficiently.
Boiler Brand | Common Boiler Faults |
Worcester | – |
Baxi | 110, E1, E2, E4 |
Ideal | Overheat Lockout, Water Pressure |
Vokera | – |
Glow-worm | F32, Boiler Locks out in 10 seconds (Air Fault), F02, F3, |
The plastic pipe, known as the condensate pipe, is used to drain the acidic waste from your boiler.
Although it is often installed outside, it is sometimes internally connected to the wastewater system. As a result, this makes condensation inside the pipe vulnerable to freezing throughout the winter. Therefore, the boiler will be stopped when the sensors detect a stoppage, preventing the boiler from protecting the system and the property.
One way to detect a frozen condensate pipe is to notice any gurgling sounds from the boiler.
Boiler Brand | Common Boiler Condensate Pipe Faults |
Worcester | EA 229, D5 |
Baxi | E133, E28 |
Ideal | Fires up for a Short Time, then turns Off |
Vokera | – |
Glow-worm | F1, F29, F4, and F28 |
Your condensate pipe can be defrosted with a few DIY techniques. Finding the stoppage is the first step, where the pipe bends or dips are typically where an ice blockage originates.
The following are a few tactics to prevent condensate pipes from freezing:
A broken diverter valve is most likely to blame if your boiler operates, but no hot water is available or vice versa. The valve sticks as a result of general wear and tear over time.
Get A Quotation
Feel Free To Contact Us For Free Consultation.
Boiler Brand | Common Boiler Gas Valve Faults |
Worcester | FA, FA 364, FB 365, F0 238, EA 234 |
Baxi | H.01 – .00, E.02 – .17, E.04 – .17, E09,E15, E134, E09, E15 |
Ideal | – |
Vokera | – |
Glow-worm | F26 / F77, F26 / F77, F14, F.61, F.82 |
The boiler’s tiny flame, known as the pilot light, ignites the gas, which heats the water constantly. When it fails, there is no heating and no hot water. Usually, the reason is that debris obstructs the jet.
On the other hand, rarely, a broken thermocouple or a draught from a window that wasn’t correctly sealed results in the light turning out.
In newer types of boilers, the error code on display will inform you if there is a problem with the pilot light, rather than in older models, where you might be able to see the light through the framework.
Boiler Brand | Common Boiler Flame Failure Codes |
Worcester | 227 V, 228 V, 306 V, 2927 B, EA, F7, EA 227 |
Baxi | E.04 – .10, E133, E128, E129, 3 Green Flashes |
Ideal | L6, LN, F2, FN, L2, L6, Flame is on before gas on , Flame loss |
Vokera | A11, A01 |
Glow-worm | F.27, F.29, F.88 |
In such a case, it is always recommended to get from a certified expert.
The boiler pressure is typically 1.5 to 2 bar when the heating is on and 1-1.5 bar when it is off. Keep an eye out for fluctuations in the water pressure metre on the boiler.
Your radiators may need to be bled if the pressure exceeds 2, or the valve may become loose. If the pressure in your boiler drops below 1, you might leak, which could be caused by recent radiator bleeding.
Boiler Brand | Common Boiler Pressure Sensor Faults |
Worcester | CE 207, H07 |
Baxi | E117, E78 |
Ideal | F1 |
Vokera | A04, AL41, AL40 |
Glow-worm | F32, F73 / F74, F9, F09, F.22, F.75, F.72 |
The boiler produces CO2 when it burns gases, which can clog the burner and make it operate incorrectly or inconsistently. Additionally, the burner ages with time, and you may require replacement.
Boiler Brand | Common Boiler Pressure Sensor Faults |
Worcester | B7, F7 228, FA 306, 283, 235, 360, 9A 361, 9U 233, B7 257, EA 261, EH 258, EC 256, F0 280 |
Baxi | E.04 – .12 |
Ideal | – |
Vokera | – |
Glow-worm | F.83, Poor Burner Pressure |
A boiler expert can replace the burner or remove the carbon buildup. Future headaches and expenses can easily be avoided if you service your boiler at least once a year.